Live CT Test Set (Type-2700)
CT Ratio Error Tester can detect abnormal (bad) current transformer(CT) by comparing the 1st and 2nd Ratio Error values.
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- South Korea
- Brand name
- EDITECH
- Payment Terms
- T/T
- Production method
- OBM
- Shipping / Lead Time
- Negotiable / Negotiable
- Category
- Electrical Equipment
Editech Co., Ltd.
- Verified Certificate
-
3
Product name | Live CT Test Set (Type-2700) | Certification | - |
---|---|---|---|
Category | Electrical Equipment | Ingredients | - |
Keyword | ct ratio error tester , current transformer ratio error test | Unit Size | 330.0 * 135.0 * 310.0 mm |
Brand name | EDITECH | Unit Weigh | 3 kg |
origin | South Korea | Stock | 1000 |
Supply type | OBM | HS code | 9030909000 |
Product Information
Applications_
CT Ratio Error Tester can detect abnormal (bad) current transformer(CT) by comparing the 1st and 2nd Ratio Error values and its Phase Angle values on the live wire line. The current transformer(CT) used here are installed mostly for the low voltage customers. This tester can determine the electric power billing rate’s accuracy by comparing voltage and current’s phase angle, thus furthering confirmation of the line’s wrong connection.
Features_
● Accurate Ratio Error measurement while using on the live wire line, detecting & finding bad current transformer(CT).
● Preventing wrong connections in the power meters from the beginning of its installation.
● The nominal Ratio Error value indication display and its data saving.
● Calculate the error rate by detecting the phase difference and non-error rate between the 1st and 2nd order current transformers (CT) for watt-hour meters..
● By detecting the non-contact voltage phase of the insulated wire, it fundamentally prevents the presence or absence of incorrect wiring of voltage and current.
Specifications_
Current detection range | CT1.(5.0∼550.0A), CT2.(0.01∼10.000A) |
Rated Primary Current / Secondary Current | 75, 100, 150, 200, 250, 300, 400, 500 / 5A |
Current Accuracy | 0~ 99.9% |
Ratio Error Measurement Range | 0~ 99.9% |
The phase angle detection resolution | Less than 1 degree |
Response time | Less than 1 second |
Current measurement | True RMS |
Voltage phase detection method | Non-contact |
Ratio Error Accuracy | ±(0.5% + 2 dgts) of F.S. |
Display TFT LCD (3.5") | CT1, CT2 Ratio Error, The phase angle difference & Incorrect wiring, ID No., Measurement Date, Battery State |
Operating power | DC 3.7V (Rechargeable Battery) |
- Product Info Attached File
B2B Trade
Price (FOB) | Negotiable | transportation | Express |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | T/T | Shipping time | Negotiable |
Editech Co., Ltd.
-
3
- President
- CHOE SANG JUN
- Address
- 25-32 LS-ro 116beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, Korea
- Product Category
- Electrical Equipment
- Year Established
- 1998
- No. of Total Employees
- 1-50
- Company introduction
-
Measuring instruments are continuously needed due to the high technology advancement and technology innovation in this century, especially for the energy, semiconductor, information & telecommunication, earth & universe science and genetic engineering.
Measuring instruments and precision instruments are indeed considered the barometers of all science and technologies. For this reason, specialized measuring instruments spur the industry’s competition capacity as well as give users the easiness of use. To further the user-convenience, incessant automated & smart measuring instruments are required.
The cope with this calls of instrument technology innovation, we, Editech, have acquired lots of engineering expertise in the field of electricity distribution coupled with its electric power quality management over more than 20 years. We also have accumulated know-how of the electricity fault diagnosis for preventing casualties from happening.
We, Editech, are proud of having had government accreditation of venture business company since 2001, and since then, Editech has made efforts incubating creative ideas & technologies. We also proudly say that Editech won the gold medal award in the world invention exhibition held in Geneva, and this led Editech one of the venture companies representing ‘technology of Korea’.
Currently, we, Editech, are still striving to lead the electrical instrument engineering by obtaining many patents as well as software licenses. To do this, Editech research center is assuming the main role of developing new & valuable world-class technologies using its researchers and engineers.
We, Editech, here promise to do our bests in satisfying the customer needs in electrical instrument industry sector and will keep on continuing research and development to keep ahead in its way.
- Main Markets
-
China
Indonesia
Malaysia
Philippines
South Korea
Viet Nam
- Main Product
Related Products
Wafer frame cassette
EM-30
Numerical Protection Relay: PAC-E100 Series
Fused silica glass, quartz glass, JGS1, JGS2, JGS3
[M2I Corporation] TOPRX1500XD, HMI, TOUCH PANEL, QUAD-CORE