Product name | V-Sorb 2800S BET surface area analyzer | Certification | - |
---|---|---|---|
Category |
Other Analyzers
Other Measuring & Gauging |
Ingredients | - |
Keyword | surface area analyzer , bet analyzer , bet surface area , adsorption analyzer | Unit Size | 70.0 * 90.0 * 70.0 cm |
Brand name | Gold APP Instruments | Unit Weigh | 70 kg |
origin | China | Stock | - |
Supply type | - | HS code | 90318090 |
Product Information
V-Sorb 2800S BET surface area analyzer introduction
V-Sorb 2800S BET surface area analyzer is researched and developed by Gold APP Instruments for single and multi-point BET (Brunauer-Emmett-Teller) specific surface area, also with Langmuir surface area and others related with SSA (specific surface area) by using static volumetric principle. Compared with other companies’ analyzers, multi pioneered techs make its performance much better, heighten accuracy and consistence of results, enhance measurement stability, all these lead to a leading level in international competitors. Analyzers designed from the user perspective and equipped with fully automated operation, user-friendly interface makes it easy to learn, imported accessories assure stability and prolong life. Perfect design, sophisticated production and strict testing guarantee to meet customers’ real demands. High cost performance of V-Sorb 2800S BET surface area analyzer easily ensure your investment profits and flexible equipped peripheral can satisfy different users’ requests.
V-Sorb 2800S BET surface area analyzer application
1. Super micro powder, nanomaterials, nanoparticle and fiber shaped specific surface area analysis.
2. Product quality control for powder materials related corporations.
3. Research institutes, universities for BET (Brunauer-Emmett-Teller) theory teaching.
4. Fuel cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc.
5. Other researches concern specific surface area performance.
V-Sorb 2800S BET surface area analyzer parameters
1. Analysis Method: static volumetric nitrogen adsorption principle
2. Versatility: Adsorption and desorption isotherms, Single and multi-point BET (Brunauer-Emmett-Teller) surface area, Average particle diameter estimation, t-plot external surface area, True density analysis, Langmuir surface area, carbon black (STSA-Statistical thickness surface area), adsorption constant C.
3. Measuring Ranges: 0.01 m2/g (by nitrogen)/ 0.0005m2/g (by krypton) to no known upper limit
4. Accuracy: repeatability errors ≤1%
5. Vacuum System: V-Sorb unique monolithic manifolds and solenoid valve control system, greatly reduce the dead volume; improve the adsorbate micro-change sensitivity; enhance pore size distribution analysis resolution; decrease connecting points; strengthen sealing performance and prolonged instrument life
6. Coolant Level Prober: V-Sorb original coolant level control system with temperature probe, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change
7. Sample Treatment: the whole treatment procedures are controlled by dedicated software, as well with a start time preset function which can realize unattended operation at night
8. Control System: programmable solenoid valve system with high integration and strong anti-interference ability, enhance instrument stability and life
9. Sample Ports: two samples analyzing and two samples degassing concurrently
10. Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, 0-1000Torr (0-133Kpa), 0-10Torr (0-1.33Kpa)
11. Transducer Accuracy: imported silicon thin film pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale), far accurate than Pirani resistance vacuum gauge(general error is 10%-15%)
12. Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.998
13. Ultimate Vacuum: 4x10-2Pa (3x10-4 Torr)
14. Vacuum Pump: built-in bipolar vacuum pump controlled by patented software which can auto control pump’s start/stop
15. Sample Types: powders, nanoparticle, fiber, flakes and other materials
16. Adsorbate Gas: high purity nitrogen (≥99.999%), Ar, Kr, CO, CO2, C4H10 etc. non-corrosive gases are optional
17. Data Acquisition: high-precision and high integration data acquisition modules, minimal error, strong anti-interference ability
18. Data Reduction: Windows®-based independent developed Gold APP Instruments softwareTM, perfect versatility, produced full featured and multi-model reports
V-Sorb 2800S BET surface area analyzer features
A: Vacuum System
1. Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum.
2. Modularity design can configure as customer requests, benefits future functions extension and instrument maintenance.
3. Germany imported bipolar vacuum pump, low noise, stable working, oil-return prevention; ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).
B: Control System
1. Industry used programmable solenoid valve system, strong anti-interference ability, convenient for installation and uninstallation.
2. Separated analysis and treatment manifolds can prevent foreign matter to contaminate manifolds in sample treatment.
C. Measures for Improving Accuracy
1. Imported silicon thin film capacitive pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale).
2. 0-10Torr (optional) and 0-1000Torr dual pressure transducers, sectional measurement in pressure range can reduce errors in low vacuum, 0-10Torr silicon thin film transducer is highly accurate than Pirani resistance vacuum gauge (general error is 10%-15%).
3. Unique monolithic manifolds system, decrease connecting points and reduce leak rate apparently.
4. Original stepping coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change.
5. Pioneered gas outlet and inlet control system can efficiently prevent sample splash in evacuation and gas inlet process, guarantee clean manifolds and sample weight unchanged, avoid zero and liner drifting caused by transducer’s macro-change.
D. Data Acquisition and Reduction
1. High precision and integration data acquisition module is easy to connect, minimal errors and strong anti-interference ability; standard 485 communication mode is good for analyzer’s applications extension and interconnection, can also conveniently switched to RS232 and USB modes.
2. Multi calculating methods for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.
Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.
- Product Info Attached File
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | L/C,T/T,Western Union | Shipping time | Negotiable |
- President
- xia pan
- Address
- room 811, new material building, No. 7th, Fenghui Mid Rd., Haidian Dist, Beijing 100094
- Product Category
- Other Analyzers
- Year Established
- 2007
- No. of Total Employees
- 51-100
- Company introduction
-
<p>
Gold APP Instruments (www.jinaipu.com), expert in gas sorption analyzers, is a high technology and originality corporation located in Zhongguancun, Beijing High-tech Industry Zone, where gathered numerous national famous universities and research laboratories.
Gold APP Instruments analyzers cover F-Sorb X400CE series based on flow gas adsorption principle and V-Sorb X800 series rely on static volumetric adsorption for surface area and pore size analysis. Further, an extremely sophisticated high pressure gas sorption analyzer H-Sorb X600 series and the revolutionary gas pycnometer true density analyzer G-DenPyc X900 series left other components far behind. Gold APP Instruments scientists have revolutionized measurement techniques and designed instrumentation to enable the accurate, precise, and reliable characterization of powdered and porous materials: battery and fuel cell materials, heterogeneous catalysts, pharmaceuticals, ceramics, carbons, zeolites, projectile propellant, cosmetics, aerospace, nanotubes, medical implants, pigments and foodstuffs, indeed any solid whose performance depends on some interaction with its surroundings through its surface.
- Main Markets
-
Australia
Canada
China
India
Nigeria
Saudi Arabia
Singapore
South Korea
Thailand
U.S.A
- Main Product
Related Products
Lactomat Rapid
CMM Probe Styli - M5 (01-5010-010TR)
SFRA45
Topcon GTS 603 Electronic Total Station
U-Prime (Environmental monitoring device)