Static Var Compensator
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Category
- Electronic Products
NextOneEnergy.Co.Ltd
- Country / Year Established
- South Korea /
- Business type
- Others
- Verified Certificate
-
10
Product name | Static Var Compensator | Certification | - |
---|---|---|---|
Category | Electronic Products | Ingredients | - |
Keyword | power factor , static var , static var compensator , zero crossing | Unit Size | - |
Brand name | - | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | - |
Product Information
1. Technical specification
Voltage : 208V ~ 480V
Frequency : 60Hz / 50Hz
Phase connection : 3 Phase Y & Delta connection
PF improved : More than 0.95
compensation speed : 4~16msec
Running condition : 25℃ (Recommend) Max 40℃ ~ Min -10℃, Altitude 1000M
2. General specification
1) SCR use Zero crossing function and do not make inrush current.
2) Controller display 1 ~63th harmonic information on LCD.
3) SVC use same Q'ty capacitor bank and switching module. Each system must
running separately if one SCR is broken do not effect to other module.
4) CT location is up to engineer. support Closed-loop & Open-loop
5) Switching module must has LED and show module’s status.
6) SVC basic function : Alarm for switching module over heat, Alarm for reactor over heat,
Resonance, Phase reverse, low voltage, Over voltage. SVC support self-checking
functionfor SCR and Capacitor.
7) Controller show each Phase voltage and current waveform.
8) Controller show capacitor working time and support capacitor changing term.
9) Controller can be set Capacitor working time and make all capacitor working in same
working time.
10) Controller show capacitor's compensate KVAR and support Electricity cost.
11) Engineer can be set the Re-start time for reactor over heat and heat sink over heat.
3. SVC CONTROLLER
A. Controller input power : 220VAC
B. Input power : 100~480V 60HZ (R, S, T, N 4line input)
C. Input current : CT 5 ea (Main R,S,T & Capacitor feed back 2ch)
D. CT Ratio : 5/5~10,000/5A
E. Response time : 4~16msec
F. Setting function : Capacitor Bank(1~12Bank), Bank combine,
Capacitor Running Time Limit
Phase system selecting (3phase Wye or Delta),
Rated voltage
Over-Voltage(100~150%), Under-Voltage(50~100%),
CT ratio(main/Capacitor bank),
Running way (Auto/Manual/Test mode)
Time, display re-flash
G. Protection function : Resonance (Rated voltage 150% , Phase reverse, lost
phase, limit running time,Low/Over voltage, Over-temperature, SCR error
H. LCD Display : 240 * 128 Graphic LCD
4. LCD Display
- Load side : Accumulate running time, Accumulate KW,
Accumulate KVA, Accumulate PF
KW (total), KVAR(total);
KVA(total), Present PF (total),
Voltage (Each Phase), Current (Each Phase), Frequency
V_thd(Each Phase), I_thd(Each Phase),
Harmonic Spectrum, Current Waveform
- Source side : KW (total), KVAR (total), KVA (Total), Present PF (Total),
Voltage (Each Phase), Current (Each Phase)
V_thd(Each Phase), I_thd(Each Phase),
Harmonic Spectrum, Current Waveform
- Capacitor side : Accumulate compensate KVAR, KW, Average PF
Each Capacitor Bank accumulate running time
Voltage (Each Phase), Current (Each Phase) V_thd,
5. SCR Switching Module
A. Control power : 220VAC 60㎐
B. SWITCHING material : SCR
C. Rated current : 3¢ 200A
D. Control Input : Digital method (Controller Output)
E. Cooling : Air cooling by FAN
F. Temperature Sensor : 55℃(alarm), 85℃(SVC stop)
G. Bank Q'ty : 1Bank
H. Indicate : Power status, SCR running status LED
6. Series Reactor
A. Running Voltage : AC600V or Customer request
B. Rated capacity : 7% of Capacitor capacity or customer request
C. Winding : Enamel Coating "H" class (180℃)
D. TYPE : DRY, Low loss type. Self-recovering type.
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- SeungHee. roh
- Address
- #1405, Kolong Digital Tower, YangpeungRo 22Gil 21, YeongDeungPo-Gu, Seoul, South.Korea
- Product Category
- Electrical Components & Telecoms
- No. of Total Employees
- 1-50
- Company introduction
-
Next One Energy.Co.Ltd is one of Expert for Static Var compensator. 3phase 208V ~ 480V. Use SCR Switching module and support Zero crossing technology.
- Main Markets
-
Kuwait
- Main Product
Related Products
A.T.T 6 Zone Mixing Amplifier ZONE-120M/240M/360M/480M/600M
Cafe Specialty A1_SELF-SERVE HOT & ICED CAFE MACHINE with various cashless payment system
Portable Hydrogen Water tumbler BlueWater700M-PEM technology
Flag Silicon Smart Phone Case cover for Apple
Mixing Amplifier (SMA-1202A)