Product Information

 

This water pipe is a world – class high - strength water pipe system. Its performance far exceeds international standards.

Standard
item

WATER
PIPE

PVC WATER PIPE

International Standard

KOR

USA

GE

UK

JAP

VP

HIVP

ASTM

AWWA

DIN

BS

JIS

Tensile Strength (Mpa)

52

45

45

43

48.3

48.3

45

45

40

Impact Strength (height/weight)

3.0m
9kg

1.6m
1kg

-

1.5m
9kg

-

-

1.6m
1kg

1.6m
1kg

1.5m
1kg

Long-term Hydrostatic (20, 42MPa)

18hours

1hours

1hours

1hours

-

-

1hours

1hours

1hours

iPVC water pipe obtained the New Excellent Product (NEP) certification from the Ministry of Trade, Industry and Energy and Green Technology and Green Technology Product certifications from the Ministry of Environment.

 

MECHANICAL/PHYSICAL PERFORMANCE OF iPVC PIPES

iPVC water pipe satisfies all requirements of NSF/ANSI 14 , 61

ASSESSMENT ITEM

AWWA

astm

WATER PIPE

Sustained Pressure Test

73, 500psi, 1000 hours

73, 470psi,1000 hours

PASS

5 Second Burst Test

73, 470psi

-

36

Acetone Immersion Test

20min, pass

20min, pass

PASS

Hydrostatic Burst Test

73, 755psi

73, 710psi

PASS

Vice Flattening Test

No Cracks

No Cracks

No Cracks

Temperature of Deflection

-

70 degrees C

75

Flammability Test

-

PASS

PASS

Izod Impact Test / 73 degrees F

-

73, 34.7 J/m

80.1 J/m

Tensile Strength Test

73, 48.3MPa

73, 48.3MPa

PASS

HDS Testing 2000h / 10000h

-

Hydrostatic Design Stress 2000h / 10000h

PASS

DIMENSION TABLE OF iPVC WATER PIPE

ASTM D 1785(Unit : in)

Nominal Size in

ASTM D 1785

O D

Wall Thickness

Length

Average

Tolerance

Schedule 40

Schedule 80

Schedule 120

Minimum

Tolerance

Weight
(kg/m)

Minimum

Tolerance

Weight
(kg/m)

Minimum

Tolerance

Weight
(kg/m)

½"

0.840

± 0.004

0.109

+ 0.020

0.231

0.147

+ 0.020

0.295

0.170

+ 0.020

0.330

10 ft

or

20 ft

¾"

1.050

± 0.004

0.113

+ 0.020

0.307

0.154

+ 0.020

0.400

0.170

+ 0.020

0.434

1"

1.315

± 0.005

0.133

+ 0.020

0.456

0.179

+ 0.021

0.589

0.200

+ 0.024

0.646

1¼"

1.660

± 0.005

0.140

+ 0.020

0.617

0.191

+ 0.023

0.813

0.215

+ 0.026

0.900

1½"

1.900

± 0.006

0.145

+ 0.020

0.737

0.200

+ 0.024

0.985

0.225

+ 0.027

1.093

2"

2.375

± 0.006

0.154

+ 0.020

0.990

0.218

+ 0.026

1.363

0.250

+ 0.030

1.539

2½"

2.875

± 0.007

0.203

+ 0.024

1.572

0.276

+ 0.033

2.078

0.300

+ 0.036

2.238

3"

3.500

± 0.008

0.216

+ 0.0.26

2.056

0.300

+ 0.036

2.781

0.350

+ 0.042

3.194

3½"

4.000

± 0.008

0.226

+ 0.027

2.471

0.318

+ 0.038

3.393

0.350

+ 0.042

3.701

4"

4.500

± 0.009

0.237

+ 0.028

2.927

0.337

+ 0.040

4.064

0.437

+ 0.052

5.144

5"

5.563

± 0.010

0.258

+ 0.031

3.963

0.375

+ 0.045

5.633

0.500

+ 0.060

7.333

6"

6.625

± 0.011

0.280

+ 0.034

5.145

0.432

+ 0.052

7.749

0.562

+ 0.067

9.868

8"

8.625

± 0.015

0.322

+ 0.039

7.746

0.500

+ 0.060

11.769

0.718

+ 0.086

16.449

10"

10.750

± 0.015

0.365

+ 0.044

10.980

0.593

+ 0.071

17.446

0.843

+ 0.101

24.191

12"

12.750

± 0.015

0.406

+ 0.049

14.515

0.687

+ 0.082

24.008

1.000

+ 0.120

34.039

 

AWWA C 900 (Unit : in)

Assessment Item

AWWA C 900

O D

Wall Thickness

Length

Average

Tolerance

DR 14

DR 18

DR 25

Minimum

Tolerance

Weight
(kg/m)

Minimum

Tolerance

Weight
(kg/m)

Minimum

Tolerance

Weight
(kg/m)

4"

4.8

±0.009

0.343

+ 0.041

4.427

0.267

+ 0.032

3.505

0.192

+ 0.023

2.564

20 ft ± 1 in.

6"

6.9

±0.011

0.493

+ 0.059

9.151

0.383

+ 0.046

7.234

0.276

+ 0.033

5.297

8"

9.05

±0.015

0.646

+ 0.078

15.731

0.503

+ 0.06

12.459

0.362

+ 0.043

9.108

10"

11.1

±0.015

0.793

+ 0.095

23.672

0.617

+ 0.074

18.732

0.444

+ 0.053

13.707

12"

13.2

±0.015

0.943

+ 0.113

33.483

0.733

+ 0.088

26.477

0.528

+ 0.063

19.382

 

KS M 3401(Unit : mm)

Nominal Size

KS M 3401

 

Outside diameter

Thickness

Length

 

Standard

Tolerance

Standard

Tolerance

 
 

16

22

± 0.20

3.0

± 0.30

·          

·         4,000

 

20

26

± 0.25

3.0

± 0.30

 

25

32

± 0.30

3.5

± 0.30

 

30

38

± 0.35

3.5

± 0.30

 

40

48

± 0.40

4.0

± 0.30

 

50

60

± 0.50

4.5

± 0.40

·          

·         6,000

 

65

76

± 0.50

5.2

± 0.40

 

75

89

± 0.50

5.9

± 0.40

 

100

114

± 0.65

7.1

± 0.50

 

125

140

± 0.80

8.3

± 0.60

 

150

165

± 1.00

9.6

± 0.60

 

200

216

± 1.30

11.1

± 0.80

 

250

267

± 1.60

13.4

± 0.80

 

300

318

± 1.60

16.1

± 1.10

 

 

 

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

PPI PYUNGWHA CO., LTD.

Country / Year Established
South Korea South Korea /
Membership
PRO
Business type
Manufacturer

11

DUNS

President
Kim Jae kyeong
Address
1085-11, Beodeul-ro, Jang-an-myeon, Hwaseong-si, Gyeonggi-do, Korea
Product Category
Pipe Fittings,Plastic Tubes & Pipes
No. of Total Employees
101-500
Company introduction

PYUNGWHA is a professional pipe manufacturer dedicated to safely supplying clean water and has succeeded in developing “iPVC pipe stronger than iron’ and has solved the issue of noise from draining in bathroom to contribute to communities.

Factory Information

Hwaseong

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My TK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more