FZW28-12(F) Branch Load Switch (Watchdog)
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- Brand name
- Beijing SOJO Electric Co., Ltd.
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Keyword
- branch load switch, load switch, watchdog
- Category
- Other Switches
Beijing SOJO Electric Co., Ltd.
- Country / Year Established
- China /
- Business type
- Others
- Verified Certificate
-
11
Product name | FZW28-12(F) Branch Load Switch (Watchdog) | Certification | - |
---|---|---|---|
Category | Other Switches | Ingredients | - |
Keyword | branch load switch , load switch , watchdog | Unit Size | - |
Brand name | Beijing SOJO Electric Co., Ltd. | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | 8537209000 |
Product Information
FZW28-12(F) Branch Load Switch (Watchdog)
FZW28 Branch load switch is named as Watchdog. If there is a fault occurs at the user side’s incoming line section, or fault occurs inside the user’s load side section and the user side protection active time setting does not cooperate with substation’s transformer protection time setting, the substation transformer line outgoing switch may automatically open. If the fault is permanent and automatic reclosing does not resolve the problem, therefore, a fault occurs at user’s side will cause the power down for the whole outgoing line from substation which is a part of power distribution network.
The user switch is the ideal equipment solving the accidents above. It’s installed in the duty point of 10kV overhead line, could automatically cut the single phase to earth fault and automatically isolate phase to phase short circuit fault to ensure the using safety of non-fault user.
Typical Function of Watchdog Switch
Auto-cut single phase to earth Fault Automatically opening the switch, abandoning the faulty branch, the users of substation and other feeders will not impacted by the fault.
Auto-isolate phase to phase short circuit fault When the substation outgoing cable protection automatically breaks due to short-circuit fault happens at branch of feeder line, the watchdog instantly switches off, abandoning the fault branch and then the substation protection recloses so the faults have been isolated that the feeder line’s users are having their power supply back.
Rapid Positioning Fault Point The action of Watchdog caused by the fault of branches of feeder line only affecting theactual fault branch, and the fault is being automatically reported to power distribution company in order to pinpoint the exact fault location, and arrange for recovery.
Monitoring the user load the Watchdog can detect and transmit the load data to power supply center to realize the real time load monitoring.
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- Zhihong Zhao
- Address
- Office 1111, Block D,Jiahua Plaza 9 Shangdi 3rd Street.Beijing,China
- Product Category
- Electrical Components & Telecoms
- No. of Total Employees
- 101-500
- Company introduction
-
Founded in 2002, Beijing SOJO Electric Co., Ltd. is a joint-stock high-tech enterprise, whose registered capital is 86.21 millon RMB. Currently there are more than 400 employees. The headquarter is located at Zhongguancun Shangdi Information Industry Zone, Beijing. The factory is located at Huairou Yanqi Economic Development Area. The land area of factory is 37012 sqm, the building area is 37800 sqm. SOJO is mainly engaged in the research, production, sales and international trading of power distribution equipments and automation equipment in the field of 35kv (or lower) power transmission and distribution.
- Main Markets
-
Australia
Bangladesh
Belarus
Brazil
China
India
Iran
Malaysia
N.Zealand
Peru
Russia
Singapore
Uruguay
- Main Product