16
Product name | Digital Hipot Tester | Certification | - |
---|---|---|---|
Category | Other Generators | Ingredients | - |
Keyword | - | Unit Size | - |
Brand name | - | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | - |
Product Information
Classification
Hipot testers are classified according to output voltage and its function.
Output
voltage |
Model
|
Current(mA)
Capacity |
Descriptions
|
Dimension
W x H x D (mm) |
N/W
(Kg) |
0~5KV
(0~2.5KV)
|
KT-5000PD- 20
|
Max. 20
|
Auto/Manual mode.
Digital type.
V. A meter. Output selection. Interface type. |
420x190x510
|
15
|
KT-5000PD- 50
|
Max. 50
|
18
|
|||
KT-5000PD-100
|
Max. 100
|
20
|
|||
0~10KV
(0~5KV) |
KT-10KPD- 20
|
Max. 20
|
620x360x640
|
reported
|
|
KT-10KPD- 50
|
Max. 50
|
||||
KT-10KPD-100
|
Max. 100
|
||||
0~20KV
(0~10KV) |
KT-20KPD- 20
|
Max. 20
|
reported
|
||
KT-20KPD- 50
|
Max. 50
|
||||
KT-20KPD-100
|
Max. 100
|
620x1440x720
|
Output voltages and Auto/Manual operation are converted by selection mode.
Dimension/ Net weight can be changeable by user's option
DC Hipot testes are also applicable.
Common specification
No
|
Items
|
Spec Value
|
1
|
Power source at 50/60\Hz 1
|
110 or 220V ± 10 %
|
2
|
Output voltage - 1
for model KT-5000PD-20 |
Mode1 AC 0~5 KV
Mode2 AC 0~2.5 KV |
3
|
Setting of current range
|
Presettable by
|
4
|
Minimum limit of flowing current
|
See 2
( low error detector ) |
1) KT-5000PD- 20 is introduced as an example.
2) The flowing current less than minimum setting current is detected as "bad"
Functions
Function
|
Descriptions
|
|
Timer ( 0~ 99 sec)
ON mode : time is counted OFF mode : presettable |
Test duration
|
Presetting time for real time test
|
Display of test result
|
Good: Lamp (Green )
|
|
Bad : Lamp(Red) & buzzer
|
||
Test types
|
Real time test
|
Tested during the setting time
|
Normal test
|
ON : Starting of test
RESET : Stopping of test |
|
Output voltage
|
Output form
|
Contact signal ( Good/Bad )
|
Other signal source (Versatility) (Max 100/1A contact) Connectable to other auto line. |
||
Ground Open Protect Circuit |
More safety | Stopping of output & Lamp (Yellow) - In case of ground wire open. |
KAST..s Hipot tester shows directly the real time leakage current through its digital ampere meter on the front panel, as compared with other tester not having ampere meter on it..s front panel.
How to proceed hipot voltage (puncture) test
High voltage withstanding shall be measured between two conductive material, for example, coil and core. Throughout this voltage endurance test, the fault or weakness of insulation, abnormal insulation and other inserted material can be checked. |
Benefits
Reliable and accurate test result
|
Interface type ( RS 232C serial port ) |
Supplied with calibration report ( ISO 17025 ) |
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- Whowon Park
- Address
- Gupyeong-dong, Gumi-si, Gyeongsangbuk-do, Korea
- Product Category
- Other Machinery & Industry Equipment
- No. of Total Employees
- 1-50
- Company introduction
-
We are bright company comprised of kind people who are grateful to share our past, present and future.
KAST has been manufacturing various types of test equipment and systems for coil winding products, electric devices, high voltage products, and electric home appliances since 1987. At present, 40 kinds of high accurate test equipment and systems are under commercial production, and ranked first in domestic market share in South Korea.
KAST's products are used in the manufacturing fields more than 2000 companies relating to motor, transformers, solenoid, car electric parts, nuclear plant, mobile phone and more.
KAST manufactures these products on the basis of accumulated experience (including patents) and the continuous R&D investment. KAST runs its own Calibrating Laboratory certified under IEC 17025.Our overseas marketing is also expanding every year and our endless efforts for exporting will continue in order to meet the increasing demands of overseas customers. With open-minded and warm hearts, we at KAST are waiting to negotiate with you.
1978.11 Established
2001.05 Patents for Surge Tester
2002.01 Designated as National Calibration Institute (ISO/IEC 17025)
2002.11 Awards (Test Equipments Parts, High Accuracy Equipments Parts)
2003.07 Designated as Superior Exporting Firm
2003.09 Designated as INNO-BIZ Company
2006.03 Certificate of NEP (New Excellent Product)
2006.11 CE Certificate for Digital Surge Tester
- Main Markets
-
Australia
China
Hong Kong(China)
Japan
Pakistan
- Main Product
Related Products
DC Motor
High Voltage Power Supply Genarator (SJ-1200 P)
Diaphragm
OZBV-05A(BLDC Velocity Control Driver)