Air Source Heat Pump

Air Source Heat Pump


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
Category
Water Heaters

Iljin E-Plus Co., Ltd.

Country / Year Established
South Korea South Korea /
Business type
Others
Verified Certificate

12

DUNS

Product name Air Source Heat Pump Certification -
Category Water Heaters Ingredients -
Keyword - Unit Size -
Brand name - Unit Weigh -
origin Stock -
Supply type - HS code 84186

Product Information

Air Source Heat Pump

Product Overview
A system that utilizes the external air for the heat pump to provide heating and hot water

Air Source Heat Pump
The system utilizes 60-80% air and 25% of electricity to provide heat thereby reducing the electricity cost.

Features

  • Simplified system which does not require a waste heat recovery device
  • Facilitating up to 70°C of the water temperature by applying a new refrigerant (IAW Series)
  • Controllable temperature of the output water and stable system by applying the inverter system
  • Enabled to store hot water in the thermal storage tank thereby offering not only the cooling but also the heating functions in winter (IACH Series)
  • Simplified system enabling auto control and easy operation

Application

  • A Any sector requiring hot water and heating including Hotel, Motel, Dormitory, Hospital, Restaurant (IAW Series)
  • Any sector requiring cooling/heating or hot water/cooling/heating (IACH Series)

Specification of Air Source Heat Pump(IAW-16A Series)

Model
IAW-16A-09
IAW-16A-13
IAW-16A-17
IAW-16A-25
Capacity
Heating
KW
30.29
44.51
60.59
88.7
Kcal/h
26,053
38,275
52,106
76,279
USRT
8.62
12.66
17.23
25.22
Power Supply
KW
12
15
24
36
Power Supply
3Phase x 380V x 60Hz
Dimension
Length
mm
2,040
2,340
2,340
3,480
Height
1,240
1,340
1,570
2,000
Depth
710
710
1,100
1,030
Compressor
Type
Scroll type
Quantity
1
2
Operation Method
Direct-on-line
Volume Control
%
0~100%
Refrigeration Ton
RT
4.32
5.6
8.64
12.52
Refrigerant
Type
R-410A
Control Method
Thermostatic expansion valve
Condenser
Type
Brazed Plate type
Circulation Volume
LPM
11
16
22
32
Piping(IN/OUT)
A
25
25
40
50
Outdoor unit
Type
Finned Copper Tube Type
Thermal Storage Area
m2
108.5
128.2
186.5
330.3
Fan & Motor
Air
Volume
m3/min
190
240
510
680
Size
Ø
450x3
500x3
630x3
630x4
Control
Temperature Control
4way proportional control valve
Operation Control
PCB
Defrosting
Hot Gas
Reverse Cycle
Weight
kg
350
500
650
750
Conditions for the products
heating
Outdoor (DB7°C); Temp of water supply to be 30°C; Temp of output water to be 70°C; T=40°C
The above specification may vary depending on the site and temperature conditions.
The above specification may change without prior notice for further improvement.

Specification of Air Source Heat Pump(IACH-16B, IACHK-16C series)

Model
IACH-16B-10
IACH-16B-13
IACH-16B-21
IACH-16B-28
IACHK-16C-39
Capacity
Heating
KW
36.16
45.7
71.44
96.74
137.21
Kcal/h
31,100
39,300
62,300
83,200
118,000
USRT
10.28
13
20.6
27.51
39.02
Cooling
KW
34.77
42.21
69.65
88.37
122.09
Kcal/h
29,900
36,300
59,900
76,000
105,000
USRT
9.89
12
19.81
25.13
34.72
Power Supply
Heat/Cool
KW
13.5/12.9
17.0/16.2
25.3/24.8
37.4/36.2
60.0/55.0
Power Supply
3Phase x 380V x 60Hz
Dimension
Length
mm
2,040
2,380
2,334
3,480
2,680
Height
1,270
1,370
1,600
2,000
2,290
Depth
710
730
1,110
1,110
2,030
Compressor
Type
Scroll type
Screw
Quantity
1
2
1
Operation Method
Direct-on-line
Y-
Volume Control
%
0~100%
Refrigeration Ton
RT
4.12
4.92
8.24
12.35
17.35
Refrigerant
Type
R-22
R-407C
Control Method
Thermostatic expansion valve
Condenser
& Evaporator
Type
Brazed Plate type
Heating
Circulation
Volume
LPM
104
131
208
277
393
Cooling
Circulation
Volume
100
121
200
253
350
Piping(IN/OUT)
A
25
25
40
50
65
Outdoor unit
Type
Finned Copper Tube Type
Thermal Storage Area
m2
108.5
128.2
186.5
330.3
522.6
Fan & Motor
Air
Volume
m3/min
190
240
510
680
1,080
Size
Ø
450x3
500x3
630x3
630x4
700x6
Control
Temperature Control
4 way proportional control valve
Operation Control
PCB
Defrosting
Hot Gas
Reverse Cycle
Weight
kg
400
550
700
800
1200
Conditions for the products
heating
Outdoor (DB7°C); Temp of water supply to be 40°C; Temp of output water to be 45°C;
cooling
Outdoor (DB25°C); Temp of water supply to be 12°C; Temp of output water to be 70°C;
The above specification may vary depending on the site and temperature conditions.
The above specification may change without prior notice for further improvement.

Air Source Heat Pump Water Heater(IAT-16A-01) & EVI Air Source Heat Pump(IAH-16A-05)

Model
IAT-16A-01
IAH-16A-05
Capacity
Heating
KW
2.8
17
Kcal/h
2,408
14,620
USRT
0.79
4.83
Power Supply
KW
0.88
6.8
Power Supply
Single x 220V x 60Hz
3Phase x 380V x 60Hz
Dimension
Length
mm
568
1,108
Height
1,670
1,075
Depth
568
568
Compressor
Type
Scroll type
EVI Scroll type
Quantity
1
1
Operation Method
Direct-on-line
Volume Control
%
0~100%
Refrigerant
Type
R-410A
Control Method
Thermostatic expansion valve
Condenser
Type
Brazed Plate type
Circulation Volume
LPM
1.1
5.1
Piping(IN/OUT)
A
20
25
Outdoor unit
Type
Finned Copper Tube Type
Thermal Storage Area
m2
0.36
1.09
Fan & Motor
Air
Volume
m3/min
8.3
83
Size
Ø
153
460
Tank Capacity
L
190L built-in type(STS)
Separate installation
Control
Temperature Control
4way proportional control valve
Operation Control
PCB
Defrosting
Hot Gas
Weight
kg
67
200
Conditions for the products
heating
Outdoor (DB20°C, WB15°C); Temp of water supply to be 15°C; Temp of output water to be 55°C
Outdoor (DB7°C, WB6°C); Temp of water supply to be 7°C; Temp of output water to be 55°C; T=48°C
The above specification may vary depending on the site and temperature conditions.
The above specification may change without prior notice for further improvement.

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

Iljin E-Plus Co., Ltd.

Country / Year Established
South Korea South Korea /
Business type
Others

12

DUNS

President
Cha Joo, Yoon
Address
126-6, Sincheon-ri, Hallim-myeon, Gimhae-si, Gyeongsangnam-do, Korea
Product Category
General Industrial Equipment
No. of Total Employees
51-100
Company introduction

Ceaseless challenge by Iljin E-Plus, this is only the beginning!

Since its inception, We, Iljin E-Plus has been leading the heat pump market in Korea while keeping the principle of 'Value Creation and Quality First through customer satisfaction backed up by technology and trust' despite of the continuous challenge over the last 20 years.

Now grown as a company specialized in general energy saving devices, the Company is about to soar up as a global entity based on its sustainable system and experience and reliability built up over the years.

We are building a technical partnership with local and overseas leading companies. We shall continue to meet the challenge to create a new myth as a general energy saving company.

Thank you.

C J Yoon/CEO

Factory Information

Iljin E-Plus Co., Ltd.

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My TK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more