Berry PM6750 bluetooth OEM multi-para patient monitor
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- China
- Brand name
- BERRY
- Payment Terms
- MoneyGram,Others,T/T,Western Union
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Keyword
- bluetooth, patient monitor, oem multi-para
- Category
- Multi-Parameter Monitor
SHANGHAI BERRY ELECTRONIC TECH CO., LTD.
- Verified Certificate
-
5
Product name | Berry PM6750 bluetooth OEM multi-para patient monitor | Certification | - |
---|---|---|---|
Category | Multi-Parameter Monitor | Ingredients | - |
Keyword | bluetooth , patient monitor , oem multi-para | Unit Size | - |
Brand name | BERRY | Unit Weigh | - |
origin | China | Stock | - |
Supply type | - | HS code | - |
Product Information
OEM multi-para patient monitor
Model: PM 6750
Item | Patient monitor module |
Six parameter | ECG, NIBP, Spo2, Resp, Tempature and PR
|
Size | 12cm*12cm*2cm
|
Install siz | 11cm*11cm
|
Weight | 80G
|
Power Supply | Singal power support, above DC 12V 2A power PCBA recommended |
Working Environment | -10 degree ~ +40 degree
|
EMC Standards | EN60601 /EN60601-1-2/IEC601-1
|
Measurement Accuracy | ±2% in stage of 70%-99% for SPO2
|
Interference Resistance Capacity against Ambient Light | Deviation is smaller than ±1%
|
testing temperature range | 20~45 degree.
|
Details of Six parameter
ECG
- Full lead: I, II, III, aVL, aVR, aVF and V1,V2,V3,V4,V5,V6
- Gain:2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV
- Scanning speed: 12.5mm/s, 25mm/s and 50mm/s
- Band width: 0.05Hz-100Hz(3dB)
- Diagnostic mode ,1-40Hz Monitor mode ,0.1-25Hz Operation mode
Heart rate
- Scope: 0 times/minute to 250 times/minutes
- Accuracy: ±2 time/minute
SpO2
- Measurement scope: 35%-100%
- Accuracy: ±2% in the range of 90%~100% ,±3% in the range of 70%-89%
NIBP
- Measurement method: Electric oscillator
- Cuff inflation time: less than 15 seconds
- Initial inflation pressure: Dynamic state 24kPa (180 mmHg)
- Measurement range:
- Systolic blood pressure: 4kPa -34kPa (30mmHg -255mmHg)
- Diastolic pressure: 2kPa -29.3kPa (15mmHg -220mmHg)
- Mean pressure: 2.7kPa~31.3kPa (20mmHg~235mmHg)
- Measurement accuracy:Static pressure: ±3mmHg
Resp
- Measurement methods: Chest impedance method or concentration of carbon dioxide at end of respiration
- Range of chest impedance method: 0 time/minute -100 minutes/minute
- Accuracy of chest impedance method: ±2 time/minute
Temp
- Single/double path
- Type: Vascular/surface temperature
- Scope: 20°C ~50°C
- Accuracy: ±0.2°C
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | MoneyGram,Others,T/T,Western Union | Shipping time | Negotiable |
- President
- Yin xuezhi
- Address
- Block C, 1/F, No.7 Building, No.1188 Lianhang Road, Minhang District Shanghai 201112 CHINA
- Product Category
- Health Care Supplement,Veterinary Instrument
- Year Established
- 2003
- Company introduction
-
About Berry
We are devoted to researching and developing, manufacturing and sales of medical electronic instrument in the monitor field. Our technology has reached the advanced level in domestic. And we have got important breakthrough on the non-invasive blood pressure calculation method, oxygen saturation detection, and multi parameter monitoring system, etc. After years of development, we have got good relationship with many customers. And the annual sales value reaches to tens of millions.
- Main Product
Related Products
Patient Monitor VP-1000
M50 Patient Monitor
Urine Analyzer CK 60
ICU & PATIENT Medical Solutions
FIA8000 Quantitative Immunoassay Analyzer