HCN-B1 Hydrogen Cyanide Sensor (HCN Sensor)
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- U. Kingdom
- Brand name
- Alphasense
- Payment Terms
- Others,T/T
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Category
- Sensors
Shenzhen ISweek Technology LTD
- Verified Certificate
-
8
Product name | HCN-B1 Hydrogen Cyanide Sensor (HCN Sensor) | Certification | - |
---|---|---|---|
Category | Sensors | Ingredients | - |
Keyword | electrochemical gas sensor , hydrogen cyanide sensor , hcn sensor | Unit Size | - |
Brand name | Alphasense | Unit Weigh | - |
origin | U. Kingdom | Stock | - |
Supply type | - | HS code | - |
Product Information
HCN-B1 Hydrogen Cyanide Sensor HCN Sensor Description
Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.
Hydrogen Cyanide (HCN)
In manufacturing, the use of Styrene Acrylonitrile (SAN) for food packaging and other consumer products has increased the danger of HCN generated during fires. Alphasense has responded to this issue with HCN sensors with fast response and stable output.
Available in A, B and D series.
HCN-B1 Hydrogen Cyanide Sensor HCN Sensor PERFORMANCE | ||
Sensitivity | nA/ppm in 30ppm HCN | 80 to 140 |
Response time | t90 (s) from zero to 30ppm HCN | < 120 |
Zero current | ppm equivalent in zero air | < ±2.5 |
Resolution | RMS noise (ppm equivalent) | < 0.05 |
Range | ppm HCN limit of performance warranty | 100 |
Linearity | ppm error at full scale, linear at zero, 40ppm HCN | 0 to 4 |
Overgas limit | maximum ppm for stable response to gas pulse | 200 |
HCN-B1 Hydrogen Cyanide Sensor HCN Sensor LIFETIME | ||
Zero drift | ppm equivalent change/year in lab air | nd |
Sensitivity drift | % change/year in lab air, monthly test | nd |
Operating life | months until 80% original signal (12 month warranted) | > 12 |
HCN-B1 Hydrogen Cyanide Sensor HCN Sensor ENVRONMENTAL | ||
Sensitivity at -20°C | % (output at -20℃/output at 20°C) at 30ppm HCN | 70 to 95 |
Sensitivity at 50°C | % (output at 50℃/output at 20 °C ) at 30ppm HCN | 100 to 115 |
Zero at -20°C | ppm equivalent change from 20°C | < 0 to -2 |
Zero at 50°C | ppm equivalent change from 20°C | < 0 to 2 |
HCN-B1 Hydrogen Cyanide Sensor HCN Sensor CROSS SENSITIVITY | ||
H2S sensitivity | % measured gas at 20ppm H2S | < 400 |
NO2 sensitivity | % measured gas at 10ppm NO2 | < -120 |
Cl2 sensitivity | % measured gas at 10ppm Cl2 | < 25 |
NO sensitivity | % measured gas at 50ppm NO | < 1 |
SO2 sensitivit | % measured gas at 20ppm SO2 | < 3 (transient) |
CO sensitivity | % measured gas at 400ppm CO | < 0.1 |
H2 sensitivity | % measured gas at 400ppm H2 | < 0.1 |
C2H4 sensitivity | % measured gas at 80ppm C2H4 | < 0.1 |
NH3 sensitivity | % measured gas at 20ppm NH3 | < 2 |
CO2 sensitivity | % measured gas at 5% volume CO2 | < 0.1 |
HCN-B1 Hydrogen Cyanide Sensor HCN Sensor KEY SPECIFICATIONS | ||
Temperature range | °C | -30 to 50 |
Pressure range | kPa | 80 to 120 |
Humidity range | % rh continuous | 15 to 90 |
Storage period | months at 3 to 20℃ (stored in original container) | 6 |
Load resistor | Ω (recommended) | 10 to 33 |
Bias voltage | V | not required |
Weight | g | < 6 |
Matched Transmitter board for HCN-B1 HCN Sensor
4-20mA Analogue Transmitter Board
• Factory calibration, custom-set for immediate use
• Wide operating voltage range
• Low RFI susceptibility
Alphasense 4 - 20 mA analogue transmitter boards provide a cost effective way for Original Equipment Manufacturers to engineer transmitter heads for fixed installation systems.
4-20mA Digital Transmitter Board
• Factory calibration, custom-set for immediate use
• Digital zero, sensitivity and temperature compensation
• Digital and 4-20mA output
• Biased or unbiased operation
• Calibration and range change
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Others,T/T | Shipping time | Negotiable |
- President
- Li xiaoyang
- Address
- 16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan
- Product Category
- Sensors
- Year Established
- 2014
- No. of Total Employees
- 101-500
- Company introduction
-
<p>ISweek is the industry sourcing and direct marketing platform launched by OFweek, Chinese high-tech web portal.ISweek has gathered abundant high-quality industrial products around the world, and is dedicated to providing one-stop product distribution and procurement services for buyers, suppliers, traders, and manufacturers of industrial technology products.For the projects of telecom communications power, dynamic environmental monitor and access networks ring controllers, we provide fully imported sensing component solutions and support the manufacturers in the industry with necessary techniques and information.In industrial auto-control and building auto-control, we provide our customers with total solutions of sensingcomponents, control systems, general cabling and system integration.The gas sensor combined with the well-developed related temperature and humidity sensors can provide the increasing programs such as air purification, environment protection and granary monitor with excellent sensing and control component services.
- Main Product
Related Products
Schmersal Sensor
Ultrasonic Sensor for Underwater
DH05 SERIES MICRO SWITCH
K SERIES COLOR MARK SENSOR
Yarn Break Detector_Yarn Break Laser Sensors: Made in Korea