Temperature Cycling Test Chambers
Fast change rates test chamber
Temperature Cycle Test Chamber
Fast change rates testing chamber is suitable for testing the changes of instruments,electrical,electronic products,machine and parts under the rapid temperature change or the the gradient conditions, takes advantage of compact, modern scroll compressors to bring fast temperature cycling to small form factor. Temperature cycling rates from 5 to 20°C/min. are possible. Two different ultimate low temperatures are available: -40°C or -70°C.
The faster cycle times can be used to meet more aggressive test methods that require thermal stress during transitions. Significant test time can be saved in completing tests, as well.
To demonstrate performance, Grande uses the international standard IEC 60068 3-5 measured at the supply air. Temperature cycles are run from hot to cold extremes, and the middle 80% of the transition is timed to determine performance. Your actual cycling results will vary depending on methodology, including the start and end temperatures, and the amount of samples loaded.
Features
QUALITY CONSTRUCTION
Stainless steel exterior and interior
Rounded interior corners for easy cleaning
Full thermal break around doorframe and door
Rotating door latch is easy and secure
Dual-layer insulation of fiberglass and expanded foam for thermal integrity
One 2" (50mm) to One 4" (100mm) diameter cable port on the left, with an impervious, flexible silicone plug
Easy lift-off service panels
Pressure relief port to allow air volume changes due to rapid temperature changes
Three levels of overheat protection
FTF PROGRAMMER/CONTROLLER
Popular PID controller with touch-screen operation
Stores 120 different profiles with up to 1200 steps each (ramp, soak, jump, auto-start, end)
Step types include: ramp, soak, jump, auto-start, and end
Ethernet interface for remote monitoring and operation
RECOMMENDED OPTIONS
Dry air purge, to compensate for quickly shrinking air during cooling, as well as to reduce risk of condensation.
Product temperature control, allows feedback from a second sensor on the product. Ensures faster completion of transition steps.
Technical parameters:
Model No GTC-225 GTC-306 GTC-408 GTC-800 GTC-1000
Working room(L) 225 306 408 800 1000
Working room(L) 500*750*600 600*850*600 600*850*800 1000*1000*800 1000*1000*1000
Inner chamber size(mm)W*H*D 1500*1930*1550 1600*2030*1550 1600*2030*1750 2100*2280*1950 2100*2280*1950
G.W.(KGs) 320 350 400 600 700
Testing temperature range -70~-150℃(KS);-40~-150℃(KL);-20~150℃(KR)
Rapid Changes Temp.Range -70℃:-50~+85℃(KS);-40℃:-20~+85℃(KL);-20℃:0~+85℃(KL)
Heating & Cooling Rate 3°C/min, 5°C/min, 8°C/min, 10°C/min, 15°C/min,20°C/min,25°C/min,,30°C/min linear average or nonlinear average
Performance Temperature range -80℃,-73℃,-60℃-40℃,-20℃,0℃,+150℃,+180℃,+200℃
Humidity range 20%RH ~98%RH(10%RH ~98%RH or 5%RH ~98%RH)
Temp.fluctuation ±2.0℃
Temp.Uniformity ±1.5℃
Temp.resolution 0.01℃
Heating rate -70~150℃<60min;-40~150℃<50min;+20~150℃<35min
Cooling rate +20~-70℃<70min;+20~-40℃<55min;+20~-20℃<35min
Material Exterior chamber material Stainless steel plate+ powder coated
Inner chamber material SUS#304 stainless steel plate
Insulation Material PU & Fiberglass wool
System Air circulation system Cooling fan
Fan Sirocco fan
Heating System SUS#304 stainless steel high-speed heater
Air flow Forced Air Circulation(It enters at bottom and leaves at top)
Humidification system Surface evaporation system
Refrigeration system Imported compressor,Tecumseh compressor,finned type evaporator,air(Water)-cooling condenser
Refrigerating fluid R23/ R404A USA Honeywell.
Condensation Air(Water)-cooling condenser
Dehumidifying system ADP critical dew point cooling/dehumidifying method
Controlling system PID Digital electronic indicators+S.S.R.With PID automatic calculation capability
Operation interface Grande Expertise in Temperature & Humidity Controller,Chinese-English Shift.
Controller Programmable capability Save 120 profiles with up to 1200 steps each
Setting range Temperature:-100℃+300℃
Reading accuracy Temperature:0.01℃
Input PT100 or T Sensor
Control PID control
Communication interface Equipped with standard communication interface devices USB,RS-232 and RS-485,enable the test chamber to be connected with personal computer(PC),to achieve multi-machine control and management at the same time.Standard: USB external memory port.Optional: RS-232, RS-485, GP-IB, Ethernet
Print function Japan Yokogawa Temperature Recorder(Optional accessories)
Auxiliary Limit Alarm,Self Diagnosis,Alarm Display(Failure Cause),Timing device(Automatic Switch)
Accessories Multi-layer vacuum glass observation window,Cable port(50mm),Controlling status indicator lamp,Chamber light,Specimen loading shelf(2pcs,position adjustable),Guaze 5pcs,Operation manual 1 set.
Safety protection device Over-heat protection circuit breaker,Compressor overload protection,Control system overload protection,Humidifying system overload protection,Overload indicator lamp.
Power supply AC 1Ψ 110V;AC 1Ψ 220V;3Ψ380V 60/50Hz
Customized service Welcome to Non-standard,Specail requirements,OEM/ODM orders.
The technical information will be subjected to change without notice
Optional accessories
1,Inner glass door with manual operating ports.
2,Temp./Humi.Recorder.
3,RS-485 interface can be linked to Personal computer(PC) and achieve multi-level control & recording software management.
4,Liquid nitrogen(LN2)/Liquid Carbon Dioxide(LCO2) fast cooling-down system