Spread of Flame Tester
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- South Korea
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Keyword
- imo-609, iso 5658, astm e 1317, imo ftp code resolution a
- Category
- Testing Equipment
BoraCEM Co,.Ltd.
- Membership
- VIP
- Recent Visit
- Dec 17, 2024
- Country / Year Established
- South Korea / 2003
- Business type
- Manufacturer
- Verified Certificate
-
10
Product name | Spread of Flame Tester | Certification | - |
---|---|---|---|
Category | Testing Equipment | Ingredients | - |
Keyword | imo-609 , iso 5658 , astm e 1317 , imo ftp code resolution a | Unit Size | - |
Brand name | - | Unit Weigh | - |
origin | South Korea | Stock | - |
Supply type | - | HS code | - |
Product Information
This equipment evaluates the combustion characteristics of building material, ship materials, etc.. It measures flame propagation speed, ignition temperature according to the distance, heat flow rate in the digestion, total heat release rate and etc.
This test method is based on ISO 5658-2 (Reaction to fire tests - Spread of flame - Part 2 Lateral spread on building products in vertical configuration) which is a method of evaluating the combustion characteristics of a specimen (155 mm x 800 mm) installed in a vertical direction.
The specimen is exposed to the appropriate radiant heat package supplied by the gas-fired radiation panel and measures the millivolt signal value with the calibrated thermocouple for the exhaust gas as the combustion progresses.
In addition, the flame propagation speed was recorded by recording the flame ignition and fire extinguishing time according to the distance of the specimen. Other test results were as follows: ignition temperature (MJ / m2), combustion sustained heat (MJ / m2) KW / m2), average burning heat, and total heat output (KW).
▣ ISO 5658-2 : Reaction to fire tests
– Spread of flame - Part 2 Lateral spread on building products in vertical configuration
▣ IMO FTP Code Resolution A. 653(16) : Recommendation on fire test procedures for flammability of bulkhead, ceiling and deck finish materials
▣ ASTM E 1317 : Standard test method for flammability of marine surface finishes
▣ All control systems are explosion proof
▣ Pilot Flame Burner of Air Cylinder type that can automatically carry out the start fire test method according to IMO
▣ Enlarged Restrict View Mirror allows you to see the ruler and easy to observe the Spread of Flame Length
▣ Radiant panel temperature controller: Prevent backfire to the rear side of the Radiant panel and check the internal temperature of the radiant panel. Installed a device that automatically blocks gas sol. v/v when back flow of fire occurs
▣ MFC (Mass Flow Controller) which makes it easy to measure the heat of methane gas when measuring critical heat flux
▣ Check-Valve and Solenoid Valve to prevent back flow of gas line and explosion proof specification of all control system for safety when burning radiation panel.
▣ Camcorder which can observe and save test state in program state during experiment
▣ Rail which facilitates measurement of heat flux of Radiant Panel at intervals of 50mm
▣ DAQ Program that makes able to use image storage device for flame propagation distance and combustion characteristics
▣ 19 "Analysis Rack that makes abe to measure flame propagation speed, critical heat flux and heat release rate
▣ IMO Program which can control air blower to easily change the calorific value of combustion in Radiant Panel Calibration
▣ Program will activate when the ignition of the copy panel fails, Flame Relay System will detect and stop the gas supply.
▣ IMO Program which is makes easy to calibrate and test. IT can print the result of IMO, ISO
Test Result
▣ Heat for sustained burning (MJ /m2)
The time from the first exposure of the specimen until the tip of the flame reaches each point multiplied by the radiant heat flux viewed through the incombustible calibrated plate at the same point
▣ Average heat for sustained burning (MJ /m2)
The average of the characteristic values measured at different positions by the continuous heat, the lower of the point characteristic values consecutive in 50 mm intervals from the first 1,500 mm point to the last point or 400 mm point
▣ Heat for ignition (MJ / m2)
The time from the initial exposure of the specimen to the point at which the tip of the flame reaches 150 mm multiplied by the heat flux at this point (provided heat flux is obtained from the pre-calibration of the test equipment).
▣ Critical flux at extinguishment (kW / m2)
Heat flux at the position where the flame propagates farthest from the centerline of the burning specimen. The recorded heat flux is obtained by calibrating the calibrator using the calibration plate.
▣ Total heat release (MJ) Total heat release during the test period
▣ Peak heat release rate (kW) Maximum heat release during the test period
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- Peter Song
- Address
- 8F,NO.802,EnC Dream Tower 8cha45, Gasan digital 1-ro, Geumcheon-gu,seoul 08592, korea
- Product Category
- Insulator,Testing Equipment
- Year Established
- 2003
- No. of Total Employees
- 1-50
- Company introduction
-
Engineering & marketing specialist group <br> 1.Established : 1. Aug. 2013
2.Philosophy : Create and Expand the market
Customer satisfaction through partnership
Credibility through our technology and activity
3. Business field : High performance provider in Industrial field
Through marketing and technology solution With our manufacturing partner 4. Activity : Value create by difference, competitive products and service
Focus on your highest priorities and EXECUTIN
5. Employee : 3 Advisors ( Fire safety, Reliability, Semiconductor )
7 specialist (Language ,English 4, Chinese:2, Japanese:1 )
- Main Markets
-
Brazil
China
Czecho Republic
India
Myanmar
Singapore
South Africa
U.A.E.
U.S.A
Viet Nam
- Main Product
Related Products
Smoke Automotive Leak Detector ALL-100
Muffle Furnace
Torque Sensor BRDM
AIT-U
Common Rail Injector Test Bench (V310EX)