Winner2000ZDE full automatic laser particle size analyzer
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- China
- Brand name
- Winner
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
Jinan Winner Particle Instrument Stock Co., Ltd.
- Verified Certificate
-
8
Product name | Winner2000ZDE full automatic laser particle size analyzer | Certification | - |
---|---|---|---|
Category |
Optical Instrument
Other Analyzers Electronic Measuring Instruments Other Measuring & Gauging |
Ingredients | - |
Keyword | laser particle size analyzer , particle size analyzer , particle size , particle size distribution | Unit Size | 1050.0 * 570.0 * 540.0 mm |
Brand name | Winner | Unit Weigh | 60 kg |
origin | China | Stock | - |
Supply type | - | HS code | - |
Product Information
Winner2000ZDE intelligent laser particle size analyzer, perform auto test, auto alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion, auto cleaning etc., really realize one-key operation. It adopt full built-in sampling system, effectively prevents large particles sedimentation problems in the circulation pipeline, ensure good accuracy. It adopts comprehensive Laser diffraction particle size measurement principle with highly sensitive ring photoelectric detector improving the test accuracy greatly, Original designed unconstrained free fitting software technology, a true reflection of the particle size distribution, to ensure truth and accuracy of the test results. Therefore especially suits the laboratories of enterprises, colleges and universities and research institutes to use.
1. Main Specifications:
Model Name | Winner2000ZDE | |
Standard | ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009 | |
Principle | MIE scattering principle | |
Measuring Range | 0.1-300μm | |
Channels Number | 39 | |
Accuracy | <1% (National Standard Sample D50 ) | |
Repeatability | <1% (National Standard Sample D50 ) | |
Light source | High performance He-Ne Laser (λ= 632.8nm, P>2MW) Lifetime>25000hour | |
Dispersion Method | Ultrasonic | Frequency:40KHz Power:35W, Time: ≥1S |
Stir | Revolutions Speed: 0-300RPM (Adjustable) | |
Circulate | Rated Flow:8L/min Rated Power:10W | |
Sample Pool | Volume:350mL | |
Micro- Sample Pool | Volume: 10mL ( Available) | |
Operation Mode | Full automatic and manual control, freely choose | |
Output parameter | D10,D50,D90,D100,S/V referent parameters | |
Optical Calibration System | Full automatic | |
Test Speed | <2mins for each time | |
Volume | L88cm×W39cm×H46cm | |
Net Weight | 41Kg | |
Warranty | 2 years |
2. Main Features:
1,Advanced design of light path:
A patented technique of Fourier transform of converging light released the scattered light at large-scattering-angles from the restriction of the aperture of the Fourier lens. The focal length is reduced to enhance the resolution of the instrument.
2,Built-in dispersion units:
We carefully aligned the stirring set-up, the ultrasonic dispersing unit and the sample circulation pipes, and fixed them inside the instrument. Such a built-in design effectively prevents the inhomogeneous dispersion and sedimentation of big particles, which can be observed in the designs that these dispersing units are separated from the instruments, where the sample circulation pipes are therefore too long, The sample will be sufficiently dispersed.
3,Unconstrained fitting techniques:
The particle analysis software uses a unique unconstrained data fitting technique that we developed to obtain data of unknown size distribution, this is particularly important for researchers.
4,Micro sample chamber (optional):
The capacity of the sample chamber is as small as only 10ml. This helps with measuring expensive/precious samples, or samples difficult to be dispersed within medium.
5,Modern measurement control:
Users can perform all measurement procedures by simply operating on the PC and have ideal results in a very short time.
6,User-friendly Operation:
manual mode and the automatic mode, freely choose, to measure according to the sample features. In some conditions (e.g. the sample have unknown features or there are special requirements for the measurements), users can make a test measurement in the manual mode first, and after having an idea of the sample features and the measurement conditions, measure the samples in the automatic mode.
7,Fully automatic light path alignment:
A precise four phase hybrid stepping motor automatically aligns the optical path and can adjust it at any moment. This releases users from manual adjusting the optical path and improved accuracy and stability of the measurement results.
8,Quick measurements:
set “ automatic” mode, all operation procedures are performed automatically,automatic water supply, automatic ultrasonic sample, stirring, circulation,background testing, sample testing,analysis , draining and cleaning, which significantly reduces the time for measurements, the full process only take 2 minutes.
9,Data analysis:
Errors in the data are rejected and the measurement results are automatically processed. Manual data processing is not necessary and the output is more standard.
- Product Info Attached File
-
Winner2000ZDE Wet Laser Particle Size Analyzer Specification.pdf
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- Mr. Zhongjing Ren
- Address
- Building F, North Area, University scientific Park,Shunhua road, High tech Zones, Jinan, Shandong, China
- Product Category
- Testing Equipment
- Year Established
- 2000
- No. of Total Employees
- 51-100
- Company introduction
-
Jinan Winner Particle Instruments Joint Stock Co. Ltd. is a high-tech enterprise dedicated to developing, manufacturing and selling particle characterizing instruments. We have been leading this industry in China for more than 20 years.
Our mission is to develop and bring to customers the most advanced particle-size-analysis solutions. Our products, from the portable range and the desk-top range, to the dry-powder analyzers and the spray analyzers, always stand in the frontier of the technical trends.
We have the first-class R&D team, with experts specialized in optics, electronics, computer science, chemistry and material science. Our president, Prof. Zhongjing Ren, has been studying particle measuring technology in China ever since 1982. He was the leader of a key project of the Seventh Five-year-research-plan of China. He enjoys a high reputation in the area of particle measuring techniques. We are in frequent cooperation with colleges and institutes for researching projects.
We are honored as 'the enterprise with the strongest capability to innovate in China’ and 'the pilot in the particle-measuring-technology in China'. We are classified into the top fifty enterprises in Asia in the industry related to particuological technologies.
Our History:1985 Prof. Zhongjing Ren directed a research project: the development of on-line cement particle analyzers, and that year this project was put into the list of the Seventh China’s Seventh Five-year-research-plan.
1990 The on-line cement particle analyzers passed the acceptance exam of China’s Seventh Five-year-research-plan The comments were ‘the pioneer of the art in China’ and ‘one of the most advanced technologies of this age’.
1993 The on-line cement particle analyzer won the gold medal at the First China’s Technology Expo.
1994 Took on a project of the Shandong province’s Eighth Five-year-research-plan which led to JL 9200 portable laser particle size analyzer, and had it patented.
1995 JL 9200 portable laser particle size analyzer was put into the list of ‘China’s most important new product’.
1996 Took on China’s Ninth Five-year-research-plan which led to JL 9300 laser dry-particle size analyzer. This invention won the third-grade ‘Award for Science & Tech. Progression in Shandong Province’.
2000 Jinan Winner Particle Technology Co. Ltd formally established.
2002 Winner laser particle size analyzer, Winner 2000, was approved by China’s Standard Material Research Center.
2003 Winner 2000 obtained the new product certificate of metrological instruments from Shandong Bureau of Quality and Technical Supervision.
2004 Winner Company obtains CMC certification.
2005 Moved to Jinan’s high and new technology industrial development zone.
2006 Approved as ‘Jinan’s High and New Technology Enterprise’
2007 Obtained ISO90001:2000 International Quality Management System Certification.
2007. Developed China’s first dynamic image particle size analyzer and passed the acceptance exam by Jinan Science Bureau. The comments were ‘the pioneer of the art in China’ and ‘one of the most advanced technologies in the world’.
2008 Developed CR128 digital correlator.
2009 Developed China’s first light correlation nano particle size analyzer
2008 Approved as ‘China’s High and New Technology Enterprise’
2010. Now Winner is ten years old, and it became a joint stock Company.
- Main Markets
-
Bangladesh
Cambodia
Hong Kong(China)
India
Indonesia
Japan
Nepal
Pakistan
Singapore
Thailand
- Main Product
Related Products
DIGITAL GAS METER
Leica TCR 805 Reflectorless Total Station
Indoor 3D Scanning LiDAR, Range Finder, ToF Sensor
Cable and Wire harness tester (MHT-610 / 705)
Torque Sensor BRDM