current transformer tester

current transformer tester


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
China
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
ct analyzer, ct tester, current transformer tester, ct testing set
Category
Power Supplies

Wuhan Huaying Electric Power Tech & Science Co.,ltd

Membership
BIZ
Country / Year Established
China China /
Business type
Manufacturer
Verified Certificate

9

Product name current transformer tester Certification -
Category Power Supplies Ingredients -
Keyword ct analyzer , ct tester , current transformer tester , ct testing set Unit Size -
Brand name - Unit Weigh -
origin China Stock -
Supply type - HS code -

Product Information

 

Tests for Current Transformer:

1 Excitation curve and parameters test
2 Turns ratio test
3 Ratio and phase error test
4 Polarity mark check
5 Winding resistance measurement
6 Secondary loop burden measurement
7 Error line curve test for protection CT
8 Transient CT parameters test
9 CT nameplate guess
10 Saturation hysteresis loop curve measurement

Tests for Voltage Transformer: 

1 Turns ratio test
2 Ratio error and phase angle error test
3 Polarity test
4 Secondary burden test
5 Winding resistance test

Applications of CT/PT Analyzer:

1 CT nameplate check
2 CT parameters check in work burden
3 CT transient parameters analysis
4 CT ratio and phase error calibration
5 PT routine test

CT PT Analyzer Function and Technical Index:

1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
2 Power supply: AC220V±10%, 50/60Hz±10%
3 Voltage output: 0.1~180V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output: 500VA
6 Maximum knee voltage measurement: 45KV
7 Current measurement:
  Range: 0~10A (automatically change range in 0.1/0.4/2/10A) 
  Error: <±0.1%+0.01%FS
8 Voltage measurement:
  Range: 0~200V (automatically change range in 1V/10V/70V/200V)
  Error: < ±0.1%+0.01%FS
9 Turns ratio measurement:
  Range:1~35000
  1~2000     error<0.05%
  2000~5000  error<0.1%
  5000~35000  error<0.2%
10 Phase measurement: error: ±2min; resolution: 0.01min
11 Winding resistance measurement: 
   Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
   Error: < 0.2%RDG+0.02%FS
   Maximum resolution: 0.1mΩ
12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree
13 CT Secondary burden:
   Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
   Error: <0.2%RDG+0.02%FS 
   Maximum resolution: 0.001ohm
14 PT Secondary burden:
   Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
   Error :<0.2%RDG+0.02%FS 
   Maximum resolution: 0.1ohm
15 PT ratio measurement:
   Range: 1~35000
   1~10000 error<0.1%
   10000~35000 error<0.2%
16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%
17 PT phase angle measurement: maximum error < 3min
18 Make evaluation for test results according to selected standards
19 Make word report for test result
20 Make word reports one time for multi-group test records on the PC
21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
22 Compare excitation curves with saved excitation curves in the same window
23 Memory capacity: >1000 groups test results 
24 Working condition: temperature: -10℃~50℃; moist: ≤90%

 

Product Info Attached File

CT PT Analyzer Brief Datasheet 2.pdf

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

Wuhan Huaying Electric Power Tech & Science Co.,ltd

Country / Year Established
China China /
Membership
BIZ
Business type
Manufacturer

9

President
Wang Lanfang
Address
4F,Building 7,Optical Valley International Headquarters Industrial Park,No.62,Optical Valley Road,WUHAN
Product Category
Testing Equipment
No. of Total Employees
101-500
Company introduction

1993.5 Huajing electric power branch of Hubei province transmission and substation engineering is the predecessor of wuhan huaying electric power, as the subsidiary company of hubei province transmission and substation company,we are specializing researching and selling electric power test equipment.
1994.7 High voltage circuit breaker analyzer, transformer oil dielectri strength tester, voltage monitor researched by oun company have been launched to market.
1994.10 Huajing electric power technology newspaper designed by our company been published.
1995.6 Electrical test equipment manual designed by our company been published.
1996.6 Insulation resistance tester produced by our company won the network access license from Hunan province electric power company.
1997.4 Wuhan Huaying Electric Power Technology Co., Ltd. was officially established, registered place is Wuhan City Dongmen electrical market.
1999.6 Our company bought office and relocated to new offical building: No. 135 , 13 floor of Campbell building in Hankou Nanjing Road, Wuhan City.
1999.9 Issued high voltage circuit breaker analyzer compnay standard (Q/WHY01-1999) by the Hubei Provincial Bureau of quality and technical supervision company.
2000.6 Wuhan Huaying company won the licence (E 01000311) of manufacturing measuring instrument by China State Bureau of Technical Supervision.
2000.6 GKD-B high voltage circuit breaker analyzer won the access license of Hubei Institute of measurement and testing technology.
2000.7 Official company website been online.
2000.8 Obtained ISO9001 quality system certification.
2001.10 GKC-B3 high voltage circuit breaker analyzer and XH-1003 Zinc Oxide lightning arrester tester won the networl access by Jiangxi Province power grid high voltage test equipment institute. 
2002.4 Won the title of "high-tech enterprise" from Wuhan Municipal People's government and East Lake high tech Development Zone Administrative Commission.
2002.9 Issued company standard (Q/WHY02-2002) of transformer oil dielectric strength tester by Hubei Provincial Bureau of quality and technical supervision company. 
2002.12 YJJ-II insulating oil dielectric strength tester won access from Hubei province Measurement Technology Research Institute, series no: (01) measurement (E) (Z0228).
2003.5 Got Wuhan city technology trading license WJS420102173-05.
2004.4 Companies registered capital increased to 5000000 RMB.
2004.9 Hubei province electric power measurement association was established, our company is the main originator and Council member of the association.
2004.10 completed the registration of foreign trade operation, access of independent right of import and export.
2004.11 CT PT analyzer researched by our company successfully put into manufacturer.
2005.6 Signed our first export orders with Indian EYNS.
2006.3 Hydraulic Turbine Governor Simulation System Tester successfully researched with Huazhong University of Science and Technology.
2007.12 HYBC-II transformation ratio tester and SGB-100A digital high voltage meter got network access by Yunnan power grid network evaluation of high voltage test equipment.
2008.1 Instantaneous signal recorder designed by our company widely manufacturer to market.
2008.1 HYBC-II automatic transformer ratio meter, HYHL-II contact resistance tester, HYYJ-501 insulating oil dielectric strength tester got through the Sate power industry of           quality inspection center.
2009.5 Issued enterprise standard (Q/WHY03-2009) of ct pt analyzer by Hubei Province Bureau of quality and technical supervision enterprise standards for filing standards 
2009.6 New generation of portable CT/PT analyzer developed.
2009.8 First competition of Hubei province electric power measurement association, HYHL-II contact resistance tester won first prize, HYYJ-501 insulating oil dielectric strength        tester won the second prize, HYGK-306 high voltage circuit breaker analyzer won the third prize.
2010.1 "Huaying power" certificate of trademark registrated successfully.
2010.2 Thermal power unit primary frequency modulation and period testing instrument successfully researched.
2011.5 HYZC-10 winding resistance tester won the network access by China Southern Power Grid Network high voltage test equipment Insititute.
2011.8 COmpany reloacted to new working building: Optical Valley International Headquarters Industrial Park,No.62,Optical Valley Road,Wuhan.
2012.2 Successfully completed the research goal of State Institute of pwer science and technology -- Research and development of insulating oil dielectric strength test calibrator.
2012.2 won the software copyright registration certification of insulating oil dielectric strength tester, transformer ratio tester, winding resistance tester, turbine governor        simulation tester, instantaneous signal recorder, ct pt analyzer.
2013.3 frequency response method winding deformation tester launched to produce, its intergrated designed is first trying in China.
2013.10 The 5rd generation of ct pt analyzer HYVA-405 successfully launch market.
2014.2 pdating of instantaneous signal recorder successfully launched market.
2014.9 Latest circuit breaker analyzer HYGK-307 researched successfully, unique circuit breaker vibration function is the first design in China.
2014.10 Declaration invention patent of "test equipment and method ot cur off time in insulating oil dielectric strength testing.
 
 

Main Markets

Austria Austria

Bolivia Bolivia

Brazil Brazil

Canada Canada

U.S.A U.S.A

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My TK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more