Cl - Ion Electrode Method HCl Analyzer
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Keyword
- Category
- Measuring & Gauging Tools
Kusung Technics Co., Ltd.
- Country / Year Established
- South Korea /
- Business type
- Others
- Verified Certificate
-
13
Product name | Cl - Ion Electrode Method HCl Analyzer | Certification | - |
---|---|---|---|
Category | Measuring & Gauging Tools | Ingredients | - |
Keyword | - | Unit Size | - |
Brand name | - | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | - |
Product Information
HCL Analyzer HCL-103
HCL Concentration in exhaust gas, which is discharged from buming up equipment of urban waste, is attracting the attention. HCL is generated from combustion decomposition of organ chlorine compounds such as vinyl chloride pl
HCL Analyzer is designed for measuring HCL concentration of HCL, serially and automatically, which is discharged from burning up equipment of urban waste based on the law of air pollution prevention. This analyzer executes the sampling of the fixed flow automatically, by micro computer control. In addition, the analyzer measures HCL in exhaust gas by quantifying chroline ion concentration of HCL by ion selective electrodes after absorbing HCL in the gass into the absorption liquid.
To discharge the pollutant exhausted from chimney pursuant to the standard of allowable exhaust, HCL Analyzer in TMS is used by regulating the diluted amount of pollutants in accordance with the concentration values indicated on the measuring instrument in link of nitrogen oxide and HCL. As Ministry of Environment has controlled HCL concentration values by lowering them continuously and will control the total discharge amount, higher accuracy and safety of the data values are required.
By the technology acquiring accurate and stable data values in reducing cost of waste incineration company and in transmitting data to Environment Corporation, exhaust concentration of air pollution can be reflected correctly, and also be contributed to the establishment of the policy against environmental pollution by the government.
Features of HCL
- Metal film electrode is applied to detecting element, so it has better reproducibility and reliability than the devices that use the existing rod electrode or magnetic stirrer type polishing electrode.
- Detecting element has temperature regulation function in its interior, so it is not affected from external temperature or chimney.
- Drainage of absorbed reagent is serially executed using tube pump.
- Sample gas amount is measured and auto-controlled by pressure sensor, so it is accurately absorbed by automatic digital control even in pressure changing of smoke tube.
- It always operates automatic measuring of analysis liquid, and is not affected from moisture in exhaust gas.
- It has high reliability of data, because checking the sensibility can be made every day by automatic sensitivity check and auto-calibration mechanism.
- It can display rate value, one-hour mean value, one-day mean value, and error by micro computer control.
- This is the system to make accurate measurement of electrode radical ion by removing noncontact section of electrode and liquid by bubble at unit area of measurement electrode of electrode radical ion.
- This is wastewater-air treatment system that has the advantage of separating gas and liquid smoothly, since it makes gas and liquid mixed smooth by gas-liquid mixing concave section at the upper part of gas-liquid separator.
Specifications
Measurement Object
|
HCL gas in chimney exhaust gas
|
Measurement Type
|
24-hour sequence automatic measurement
|
Structure
|
Indoor Independent type(standar)
(Option: Outdoor Independent type, Non-explosive watertight structure) |
Measurement Range
|
0-20/50/150ppm
|
Measurement Method
|
Chloride Ion Electrode method
|
Repeatability
|
within ±2%FS(by equivalent liquid)
|
Zero Drift
|
within ±2%FS/Day(by equivalent liquid)
|
Span Drif
|
within ±2%FS/Day(by equivalent liquid)
|
Response Speed
|
Within 5 min. of 90% response (by equivalent liquid)
|
Sample Flow rates
|
500mL/min
|
Sample Tube Length
|
Standard 10m
|
Absorption Liquid
|
20L(replacement by 1 time/2weeks)
|
Liquid Flow Amount
|
Approx. 0.8mL/min
|
Display
|
Measurement value, time and measurement mode, etc.
|
Calibration method
|
2-point calibration by equivalent liquid, Manual/Auto, Remote
|
External Input
|
4-20mA DC
|
Contact Signal Output
|
Power cut-off, in regulating, malfunction, abnormal concentration and close contact output
|
Coated Color-Main body
|
Manin body:5Y7/1, CELL: Black
|
CPU:5Y7/1
|
|
Power
|
AC 110V/220V 60Hz
|
Electricity Consumption
|
400VA(Main body and Porbe are included)
|
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- Hwasung Kang
- Address
- 586-15, Gwansan-dong, Deogyang-gu, Goyang-si, Gyeonggi-do, Korea
- Product Category
- Gas Disposal
- No. of Total Employees
- 1-50
- Company introduction
-
Our company, starting its business in August 2001, is a manufacturer and distributor of water quality measuring instrument and automatic sequence measurement system of chimney The company is also supplying PID Control and Aeration Tank Control System applying dissolved oxygen gauge, Electronic Dehumidifier (patented product) in high performance Peltier system, a gas pre-treatment device of chimney TMS, Dust Analyzer (dry type, wet type: patented product) of light scattering method utilizing light scattering of infrared.rays, HCl Analyzer (patented product) for chimney exhaust gas by ion selectiveelectrodes method, Sampling Probe (patented product) of exhaust gas, Velocity (flow) Meter in Pitot system, and TMS: Clean Sys. CEMS, an automatic sequence measurement system of chimney exhaust gas including Data Logger and control program.
- Main Product
Related Products
Bluetooth type ultrasonic level transmitter
Load Cell BCH
Smart Fuel Cell Kit
Torque Sensor BRTL
CMM Probe Styli - M5 (01-5008-010TR)