Gas(Nox/SO2/CO) Analyzer
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Keyword
- Category
- Measuring & Gauging Tools
Kusung Technics Co., Ltd.
- Country / Year Established
- South Korea /
- Business type
- Others
- Verified Certificate
-
13
Product name | Gas(Nox/SO2/CO) Analyzer | Certification | - |
---|---|---|---|
Category | Measuring & Gauging Tools | Ingredients | - |
Keyword | - | Unit Size | - |
Brand name | - | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | - |
Product Information
The Principle of GAS measurement
Generally, molecules absorb their own vibration and rotation spectrum when being radiated of infrared rays. Gas concentration in the sample is measured by using non-dispersive infrared ray analyzer by applying optical absorption at 7.3m(7,300nm) and 5.3m of infrared ray field.
Features of Gas Analyzer
- Stable measuring can be made due to long life of infrared ray source.
- It has high response speed
- High-speed measuring can be made.
- It has less interference due to interruption ingredients.
- Easy maintenance can be made.
- It has good operation with high precision and multi-functions with microprocessor.
- It has built-in alarm function to output max/min contact output.
- Improvement of precision of Zero/Span calibration can be made easily by pressing each control key.
- Max. 1:20 range ratio is possible at standard two-range, by applying mass flow type detector with high speed and high reliability.
- Sample switching system and planetary differential system are also used for measuring besides standard system. Infrared ray source of light, rotation sector, sync signal, contact output, range identification signal, solenoid valve drive signal, output in the middle of calibration, transfer value, indirect compensation detector, detector AC voltage amplifier, gauge change, etc.
Specifications
Measurement Method
|
SO2/Nox/CO/CO2/CH4-NDIR
|
Measurement Range
|
SO2 : 0~100ppm 10%
NOx : 0~0~100-5000ppm CO : 0~500ppm 100% CO2 : 0~50ppm 100% CH4 : 0~500ppm 100% |
Zero Drift
|
within ±2% FS/week
|
Span Drift
|
within ±2% FS/Week
|
Linearity
|
within ± 2% FS
|
Response Time
|
within ± 0.5% FS
|
Sample flow rate
|
0.5 ± 0.25L/min
|
Output
|
4~20mA DC
|
Power
|
100/220VAC, 50/60Hz
|
Size
|
483(W) x 690(D) x 177(H)mm
|
Weight
|
Approx 22kg
|
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- Hwasung Kang
- Address
- 586-15, Gwansan-dong, Deogyang-gu, Goyang-si, Gyeonggi-do, Korea
- Product Category
- Gas Disposal
- No. of Total Employees
- 1-50
- Company introduction
-
Our company, starting its business in August 2001, is a manufacturer and distributor of water quality measuring instrument and automatic sequence measurement system of chimney The company is also supplying PID Control and Aeration Tank Control System applying dissolved oxygen gauge, Electronic Dehumidifier (patented product) in high performance Peltier system, a gas pre-treatment device of chimney TMS, Dust Analyzer (dry type, wet type: patented product) of light scattering method utilizing light scattering of infrared.rays, HCl Analyzer (patented product) for chimney exhaust gas by ion selectiveelectrodes method, Sampling Probe (patented product) of exhaust gas, Velocity (flow) Meter in Pitot system, and TMS: Clean Sys. CEMS, an automatic sequence measurement system of chimney exhaust gas including Data Logger and control program.
- Main Product
Related Products
Osteopro (X-ray Bone densitometer, DEXA)
SSD : Digital Differential Pressure Gauge
Load Cell BCH
Smart Fuel Cell Kit
CMM Probe Styli - M5 (01-5008-010TR)