Product Information
Elastic sealing agent
RE-3000 is a product made of epoxy resin as main component. Lt can be used for joint part with crack of concrete structure with vibration as it has elasticity (plasticity) after hardening. Lt is the product applied to injection method to inject the agent to the place which is hard to work with V-cutting or U-cutting by grinder. Lt has excellent adhesive power and elasticity after hardening.
Features
- lt has excellent adhesive power and good tensile elongation.
- lt is easy to do injection work as ti has long pot life
- There is no shrinkage as heat is not generated in hardening.
Uses
- Crack part of concrete structure with vibration.
- For injection of joint part of the structure.
- injection of construction joint part of the structure.
General properties
RE - 3000 | Remark | ||||
ltem | Resin | Hardener | |||
Contents | Epoxy | Poly amid amin | |||
Appearance | White | Dark gray | |||
Mixture ratio/weight | 100 | 100 | |||
Gravity | 1.78 | 1.6 | |||
Pot life(Min) | 60 over | 25±2â | |||
Package unit | 10kg | 5kg |
Mechanical property
RE-3000 | Test method | ||||
Adhesive strength (N/mm2) | 3.0 + | KS F 4923 | |||
Tensile strength (N/mm2) | 1.0 + | KS F 4923 | |||
Hardening shrinkage (%) | 3 - | KS F 4923 | |||
Tensile elongation (%) | 30 - | KS F 4923 |
How to use
lt should be used with after mixing resin with hardener with correct mixture ratio as it is two liquids phase. Pot life may be vary from temperature and the amount of mixture. Lt the amount of mixture is large or the temperature of the place is high, pot life and hardening time becomes fast. lf possible, use small amount of resin and hardener when injecting with structural injector or single liquid phase grouting injection pump (SGI-100, SGI-200) and use the mixture as soon as possible without delay. Particularly, make a mixture in small amount for injection in summer and increase the temperature of the resin in winter. inject the agent into V- cutting or U-cutting part with stirring after weighing the resin and hardener correctly (resin 1kg and hardener 0.5kg) (refer to injection method).
Equipment, instrument and cleaning agent
Use iron hera or rubber hera in sealing work. Clean the equipment or tools used immediately after working with toluene, acetone, MEK or epoxy thinner.
Precautions
- Please wear proper safety equipments including helmet, protective glasses, gloves and working cloths when handling the agent.
- Wipe out immediately and wash with soaping water when skin is stained with the agent.
- Please show a doctor if there is eruption of skin by staining with the agent.
- Install a ventilator at working place to get fresh air.
- Keep correct mix ration when mixing resin and hardener in case of two component type grouter.
- Clean out instruments or equipment used for working with thinner etc.
- Mix smaller amount of resin in summer as pot life, drying time, hardening time of epoxy resin may differ by temperature or mixing amount. increase the temperature of resin in winter season. Pot life : Time period of work with the mixture of resin and hardener.
Drying time : Time period from the property of mixed resin begins to change to the time of hardening . After this time, we can not work with the mixture.
Hardening time : The time to get mechanical strength as the agent hardens completely( it should be at least 7 days and final strength can be measured at this time). - Do not use if it is below than 5â except unavoidable situation.
- Please refer to MSDS (Material Safety Data Sheet) for proper handling.
How to keep
Keep it dry and cool place without moisture after sealing the cover to prevent contacting with the air. Proper keeping temperature is 15~30â Keeping period of the liquid is 6 months. However, use the agent as soon as possible as it may deteriorate by keeping condition.
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- Jae Jun, Lim
- Address
- 1F, Yongdoo Bldg., 740-2, Yongdu-dong, Dongdaemun-gu, SEOUL, KOREA
- Product Category
- Other Chemicals,Other Constructions
- No. of Total Employees
- 1-50
- Company introduction
-
ln introducing ourselves to you we are pleased to comment that we have been engaged in one-component polyurethane resin product,one-componet grouting injection pump mashine, various packers, two-component ARC(Acrylic Resin Chemical) procuct of all descriptions to all over the S.Korea and some other nations enjoying a good reputation for a good many years.
We may state that should you favorably consider our proposal and favor us with inquiries for your specific requirements we are in a position to supply you with A1 goods at competitive prices.
We look forward to your early and favorable reply.
- Main Markets
-
Malaysia
- Main Product
Related Products
AntiBac Mobile Phone Sterilizer
Close Type Spring Mount (SMB)
Aerial Work Platform - Boom Lift Truck HS450S
K-SPACE MASTER
Open Type Spring Mount (VOS-1)